Bought a new house (~750 sq ft) with daikin minisplits, one downstairs (FTXS18LVJU) and two upstairs (CTXS07LVJU). Was having issues with them randomly shutting off and throwing UH error code and one daikin being 10x colder than others. daikin sent out a contractor (which is bs btw, do they not have dedicated techs that just inspect?) and he said the tubing was wrong and it was a $3000 fix. thought it was fishy, had a 2nd hvac guy come out and he said heat pump (4MXS36RMVJU) had low refrigerant and filled it back up. now all blow fairly cold, but if i turn off one of the daikins, then they still go into error mode UH after ~30 mins. any thoughts?
Daikin AC Units split- Errors UH and A5
Daikin error code U0 - 00 on a 4 months old system
UH and A5 error code daikin minisplits
Daikin Split zeigt Fehlercode A5/UH an, wenn auf Kühlen eingestellt?
Videos
Hey, I have a dual split system with one outdoor condenser unit (2MXS18PMVM) connected to two indoor evaporator units (CTXSO9PMVM5), installed in separate rooms. One of the indoor units started displaying the error code "UH". The other unit is showing an error code "A5". I can't turn on neither of them. Currently there's quite the heatwave where I live, so something might have overheated.
My immediate attention is on the unit showing the "UH" error, as it's where I sleep (the other one is in an empty guest room). If I were to temporarily turn off the unit showing the "A5" error (which I read it might be a problem on the indoor heat exchange of that unit), would it allow the other unit (with the "UH" error, which afaik is a communication/transmission error) to turn on? I'm hoping to at least get the ac on my room running properly until I can get professional help. I'm wondering if anyone has insights into what might be causing these errors or how to fix the one in my room until I'm able to schedule technicians to come look at it
EDIT: After turning on and off all of my apartment circuit breakers, I could the on in my room on, even though it doesn't refrigerate, just ventilate... And the other one is showing that it has the "C4" error
Hey all,
Firstly, I've already written the installers. But seeing it's a weekend, I'm unlikely to get anything back until Monday I recon.
Anyways, in short, today, my (relatively) newly installed Daikin HVAC faulted out, with all internal units spewing a U0 - 00 error. I had a google and it looks like the error is refrigerant related. Which makes me worry if its leaking?
I don't know much about HVAC systems, but how risky is it if this is leaking? its R32 gas in there, is it safe to stay in the property for family (and pets) if there is a possible leak on the system?