JustAnswer
justanswer.com › australia-whitegoods › 80fux-code-u1-showing-flashing-dikin-air-con-controller.html
How to Fix Daikin Error Code U1: Expert Solutions
First, power off the system and check wiring connections for loose or damaged cables. Inspect the indoor unit’s PCB and sensors for faults or corrosion. Reset the controller by turning off power for 5 minutes, then restart.
🌐
Daikin
daikin.com › products › ac › services › error_codes
Error Codes | After Sales Service | Air Conditioning and Refrigeration | Daikin Global
Error Code Search offers information on the cause of the malfunction and the status of your air conditioner by entering the error code.
People also ask

How do you reset a Daikin fault?
To reset a Daikin fault, you must enter the diagnostic mode using the remote control to retrieve the fault code.  Then, use the On/Off button to reset the unit.  If the fault persists, professional assistance may be required.
🌐
penair.com.au
penair.com.au › home › how to reset a daikin air conditioner
Daikin Troubleshooting: Error Codes & Resetting A Daikin
Where is the reset button on a Daikin?
The reset function for a Daikin air conditioner is typically activated through the remote control.  Instead of a separate reset button, the On/Off button acts as the Daikin Air Conditioner reset button.
🌐
penair.com.au
penair.com.au › home › how to reset a daikin air conditioner
Daikin Troubleshooting: Error Codes & Resetting A Daikin
Why is my Daikin air conditioner not starting?
If you experience issues like your Daikin AC not turning on, check for any power supply issues first.  If the power supply is fine, try resetting the unit using the remote control.  Persistent starting issues might indicate a more serious problem needing professional attention.
🌐
penair.com.au
penair.com.au › home › how to reset a daikin air conditioner
Daikin Troubleshooting: Error Codes & Resetting A Daikin
🌐
JustAnswer
justanswer.com › australia-whitegoods › 58gw0-error-code-u1-solution-daikin-model-brc1e61-indoor-unit.html
How to Fix Daikin Error Code U1: Expert Solutions and Troubleshooting
After a power outage, check wiring connections for looseness or damage. Reset the system by turning off power for 5 minutes, then restart. Inspect the PCB boards for faults or corrosion.
🌐
RemoveandReplace.com
removeandreplace.com › home › home air conditioning › daikin air conditioner ac error codes
DAIKIN Air Conditioner AC Error Codes
December 22, 2022 - Daikin AC Error Code = M8 Error Code Definition = Malfunction of transmission between optional controllers for centralized control – Centralized control power disconnection What To Fix/Check/Replace = Centralized control reset switch ON – Defective transmission wiring – Central remote controller change
🌐
Reddit
reddit.com › r/hvac › help - daikin 20kw ducted system is throwing a u1 fault code
r/HVAC on Reddit: HELP - DAIKIN 20kw ducted system is throwing a U1 fault code
October 31, 2025 -

DAIKIN 20kw ducted system is throwing a U1 fault code.

We did change the power and incorrectly orientated the phases but have rectified this issue but we can’t clear the code to restart the unit.

I have continuity checked all the fuses on the PCB’s and carried out numerous power off resets including one over night but the fault code persist.

I think the indoor controller is just telling the out door unit it has a problem at this point.

Have cleared the fault off the remote but the out door unit still won’t start.

PCB’s don’t have any visible issues.

Any ideas on what to try next?? We really need this thing going as it’s being used for temperature control in a factory.

🌐
JustAnswer
justanswer.com › hvac › roaz1-u1-error-code-daikin-controller-not-know.html
Daikin U1 Error Code: Troubleshooting Guide & Solutions
The U1 error on a Daikin AC typically ... the indoor unit’s PCB and sensors for faults. Reset the system by turning off power for several minutes....
🌐
Penair
penair.com.au › home › how to reset a daikin air conditioner
Daikin Troubleshooting: Error Codes & Resetting A Daikin
November 10, 2025 - Dealing with a malfunctioning air conditioning system can be frustrating, but resetting your Daikin air conditioner can often resolve many common issues. This updated guide for 2024 provides step-by-step instructions on resetting Daikin ducted, split-system, and multi-split system units, decode error codes, and troubleshoot common problems.
Find elsewhere
🌐
Daikin ONE
daikinone.com › smart_thermostats › oneplus › pros › PhaseTwoErrorCodes.pdf pdf
Climate Talk Fault Code Dealer error code Possible causes Corrective actions
Climate Talk Fault Code · Possible causes · Corrective actions · Unit Type · Alarm Status · Thermostat Communication Alarm · Thermostat Internal Hardware · Alarm · Alarm Category · Pressure Alarms
🌐
Daikin-airconservice
daikin-airconservice.ru › f › si30-701.pdf pdf
Pocket Manual Service Diagnosis Si30 - 701_A
code · Troubleshooting · Description of error · Description of diagnosis · Troubleshooting by Remote Controller · 45 · U1 - 01 · Reverse phase/open phase · for power supply (Master) Refer to the “U1” flow chart of · each manual and make a · diagnosis of the relevant unit ·
🌐
Star-supply
star-supply.com › content › Daikin-Troubleshooting Codes.pdf pdf
Trouble Shooting www.climatecenter.co.uk Daikin Trouble Shooting Guide
Capacity setting error · Incorrect capacity setting · • · • · Trouble Shooting · www.climatecenter.co.uk · Daikin Trouble Shooting Guide · Past & Current Models · Daikin Fault Codes · System Fault Codes · Fault Code · Definition · Supposed Causes · Split · Skyair · VRV · Package · HRV · U0 · Shortage of refrigerant · Undercharged, EEV fault, faulty sensor · • · • · • · • · U1 ...
🌐
Airway Group
airway-group.co.uk › home › help & advice › daikin air conditioning fault codes explained [infographic]
Daikin Air Conditioning Fault Codes Explained [Infographic] | Airway
April 2, 2026 - U1 – Reverse phase – The three phase power supply has been reversed. U2 – Open phase or power voltage imbalance – There may be an open phase or a voltage imbalance in the power supply.
🌐
CoolAutomation
coolautomation.com › blog › daikin error codes: comprehensive breakdown
Daikin Error Codes (Malfunction Self-Diagnosis)
July 20, 2025 - Other centralized control power disconnection Centralized control reset switch ON Defect of transmission wiring Central remote controller address change
🌐
Daikin
my.daikin.eu › content › dam › DASW › supportavdelningen › Felkoder_SM-TS3errorcode_chart.pdf pdf
Simple Self-Diagnosis by Malfunction Code After Sales Service Division (SM-TS3)
U1 · Reverse phase, open phase · Power supply reverse phase · T phase open phase · Defective outdoor unit PCB (A1P) k k k k k k k · U2 · Malfunction of power supply or · instantaneous power failure · Abnormal power supply voltage · Instantaneous power failure · Defective main circuit ...
🌐
Daikin India
daikinindia.com › product-services › product-services › error-codes
Error Codes | Daikin
The remote controller can receive relevant error codes from the indoor unit. The code indication changes as shown below, and notifies with a long beep. ... Customer Support Information: WhatsApp us your query @ 9871409300. Call Our Customer Contact Centre: 011-40319300 / 1860 180 3900 or Write To Us at customerservice@daikinindia.com X
🌐
Airconditioningmackay
airconditioningmackay.com.au › home › daikin air conditioner error codes
Daikin Air Conditioner Error Codes and Troubleshooting Faults
January 22, 2026 - The list below features all the malfunction error codes for Daikin air conditioners and their potential causes.
🌐
HVAC Toolkit
hvactoolkit.org › home › resources › error codes › daikin
Daikin Error Codes - Complete Fault Code List & Solutions | HVAC Toolkit
Complete Daikin error code list for mini-splits, VRV systems, and air conditioners. Find meanings, causes, and troubleshooting solutions for all Daikin fault codes.
🌐
Whirlpool
forums.whirlpool.net.au › home › air con › daikin error code: u1-04
Daikin error code: U1-04 - Air conditioners
Our Daikin has been very unhappy at times when power is dropped by blackout when it was running, What makes it worse is it will reset (Power) for 20 sec or so then dropout again. The Air con would not work and had error codes.