How many condenses do you have? Is one a multi head? Does the fault occur when all the heads from the multi head are turned on or only when one is turned off? If one is running, does the other heads coil get cold while off? No? Turn the on and the other off If possible send a pic of the piping coming out of the condenser Answer from Nerfixion on reddit.com
🌐
Penair
penair.com.au › home › how to reset a daikin air conditioner
Daikin Troubleshooting: Error Codes & Resetting A Daikin
November 10, 2025 - To reset a Daikin fault, you must enter the diagnostic mode using the remote control to retrieve the fault code. Then, use the On/Off button to reset the unit.
🌐
Reddit
reddit.com › r/hvacadvice › uh and a5 error code daikin minisplits
r/hvacadvice on Reddit: UH and A5 error code daikin minisplits
June 24, 2023 -

Bought a new house (~750 sq ft) with daikin minisplits, one downstairs (FTXS18LVJU) and two upstairs (CTXS07LVJU). Was having issues with them randomly shutting off and throwing UH error code and one daikin being 10x colder than others. daikin sent out a contractor (which is bs btw, do they not have dedicated techs that just inspect?) and he said the tubing was wrong and it was a $3000 fix. thought it was fishy, had a 2nd hvac guy come out and he said heat pump (4MXS36RMVJU) had low refrigerant and filled it back up. now all blow fairly cold, but if i turn off one of the daikins, then they still go into error mode UH after ~30 mins. any thoughts?

Top answer
1 of 6
2
How many condenses do you have? Is one a multi head? Does the fault occur when all the heads from the multi head are turned on or only when one is turned off? If one is running, does the other heads coil get cold while off? No? Turn the on and the other off If possible send a pic of the piping coming out of the condenser
2 of 6
2
What you have is a Daikin Multiport. The problem is likely that the installing contractor mixed up the wiring from the outdoor to the indoor units. Daikin Multiports come with a fix from the factory for this as it’s a common issue. Turn off all indoor units from the remote controllers or thermostats. Remove cover above where the copper line sets leave the outdoor unit by way of two Phillips head screws. You will see a circuit board to the left with several LED lights (4-5 lights). Turn off power to outdoor unit by way of the breaker or the disconnect. Cycle power back on and wait for 5 minutes. Press and release the SW3 button located on the board to the left being very careful not to touch any of the wiring labeled A, B, C, etc. as these wires will have 208-230V active on them. This has initiated the wrong wiring check. If the check has been initiated you will see a flashing pattern of red lights on the board on the left. The test will then run for 10-20 minutes at which time the outdoor unit will shut off. If there were any inconsistencies in the wrong scheme from the outdoor to any or all of the indoor units, then the outdoor unit will automatically correct the wiring internally through the board logic and no physical change will be needed of the wiring scheme. What is basically happening when the wires from A, B, etc. do not correspond correctly to the Port A, Port B, etc. is that the refrigerant goes to an air handler that the blower is not currently running on or is running on low-low, so that the indoor unit begins to freeze up and an A5 error code is given. As you’ve said, the problem doesn’t happen when all indoor units are running as it doesn’t matter at that point that the refrigerant is going to wrong indoor unit as refrigerant is going to all indoor units and all indoor blowers are running. For years this has been the very first thing I do when I come upon a Daikin multiport as I’ve no idea who has been there before me, or if the installer did it correctly or not. It should be noted also that this change is stored in the PCB on the outdoor unit. So in the future if the outdoor unit circuit board is ever replaced or if the entire outdoor unit replaced, the wrong wiring check will need to be done again or else you’re back in the same boat as before.
Discussions

A5 error code. Daikin ftxs12lvju. Haven't been able to find
A5 error code. Daikin ftxs12lvju. Haven't been able to find info on what to do with A5 error code More on justanswer.com
🌐 justanswer.com
1
December 14, 2023
UH and A5 error code daikin minisplits
How many condenses do you have? Is one a multi head? Does the fault occur when all the heads from the multi head are turned on or only when one is turned off? If one is running, does the other heads coil get cold while off? No? Turn the on and the other off If possible send a pic of the piping coming out of the condenser More on reddit.com
🌐 r/hvacadvice
28
4
June 24, 2023
Daikin Split gives A5/UH error code when set to cool?
🌐 r/hvacadvice
Daikin Split-Unit...A5 error message
Having the same issue now unit is only 11 months old. Had people out here twice. Said it looks fine of course works fine when they are here. Was yours fixed? More on reddit.com
🌐 r/hvacadvice
7
2
December 19, 2023
People also ask

Where is the reset button on a Daikin?
The reset function for a Daikin air conditioner is typically activated through the remote control.  Instead of a separate reset button, the On/Off button acts as the Daikin Air Conditioner reset button.
🌐
penair.com.au
penair.com.au › home › how to reset a daikin air conditioner
Daikin Troubleshooting: Error Codes & Resetting A Daikin
How do you reset a Daikin fault?
To reset a Daikin fault, you must enter the diagnostic mode using the remote control to retrieve the fault code.  Then, use the On/Off button to reset the unit.  If the fault persists, professional assistance may be required.
🌐
penair.com.au
penair.com.au › home › how to reset a daikin air conditioner
Daikin Troubleshooting: Error Codes & Resetting A Daikin
Why is my Daikin air conditioner not starting?
If you experience issues like your Daikin AC not turning on, check for any power supply issues first.  If the power supply is fine, try resetting the unit using the remote control.  Persistent starting issues might indicate a more serious problem needing professional attention.
🌐
penair.com.au
penair.com.au › home › how to reset a daikin air conditioner
Daikin Troubleshooting: Error Codes & Resetting A Daikin
🌐
Airchillac
airchillac.com › daikin-ac-error-codes
Daikin AC Error Codes Guide – Fixes, and Troubleshooting Tips | AirChill AC Maintenance and Duct Cleaning
June 5, 2025 - Sometimes the error will stay even after the issue is fixed. In that case, you can try to reset the AC. Turn off your Daikin AC. Press and hold the “Cancel” button on the remote.
🌐
CoolAutomation
coolautomation.com › blog › daikin error codes: comprehensive breakdown
Daikin Error Codes (Malfunction Self-Diagnosis)
July 20, 2025 - Other centralized control power disconnection Centralized control reset switch ON Defect of transmission wiring Central remote controller address change
Find elsewhere
🌐
U Sin Aircon
usinaircon.com.sg › daikin-error-code-a5-troubleshooting
Fix Daikin Error Code A5: Simple Solutions & Prevention Tips
October 22, 2024 - Fix Daikin Error Code A5 with simple steps. Learn the causes and prevention tips to keep your aircon running efficiently and your home comfortable.
Call   +6590615191
Address   31, Woodlands Close #05-09,, 737855, Woodlands Horizon
🌐
Mytour
mytour.vn › home › travel › decoding daikin's a5 error code: origins and detailed solutions
Daikin A5 Error Code: Causes and Detailed Solutions | Mytour.vn
November 6, 2024 - To accurately diagnose the issue with your Daikin air conditioner, follow these steps: + Step 1: Direct the remote control towards the indoor unit. + Step 2: Press and hold the CANCEL button for 5-7 seconds until the remote control's screen ...
🌐
Silverback Air-con
silverbackaircon.sg › home › aircon error code › daikin error code › daikin a5 error code and how to fix it
Daikin A5 Error Code and How To Fix It - Silverback Air-con
February 23, 2024 - If you are wondering what the Daikin A5 error code is, a simple search on google will give you an answer. It is stated that the error code means that there is a high pressure control in heating, freeze up control in cooling. The reason why you are in this article is likely to know more about what this means and how to fix it.
🌐
Trane
partshnc.com › blog › how-to-reset-your-daikin-air-conditioner
How to Reset Daikin Air Conditioner: A Comprehensive Guide
March 11, 2024 - The air conditioner reset button location is near the control panel or on the unit itself. Refer to your unit’s user manual for specific instructions. ... To reset a Daikin error code, you can unplug the air conditioner from the power source ...
🌐
Lioncityaircon
lioncityaircon.sg › home › home improvement › daikin aircon error codes explained (full list + fix guide 2026)
Daikin Aircon Error Codes: Full List + What to Do (2026)
August 23, 2024 - These are the small wireless remotes that come with most Daikin split aircons in Singapore homes. If you’re using a typical Daikin in an HDB flat or condo, this is probably your remote. ... Hold the Timer Cancel button for 5 seconds.
🌐
JustAnswer
justanswer.com › hvac › nnj5r-a5-error-code-daikin-ftxs12lvju-haven-t-able-find.html
A5 Error Code Daikin FTXS12LVJU? Expert Troubleshooting Guide
December 14, 2023 - First, check the wiring connections for loose or damaged cables. Inspect the PCB boards for signs of corrosion or burn marks. Reset the system by turning off power for five minutes.
🌐
Daikin
daikin.com › products › ac › services › error_codes
Error Codes | After Sales Service | Air Conditioning and Refrigeration | Daikin Global
Error Code Search offers information on the cause of the malfunction and the status of your air conditioner by entering the error code.
🌐
HVAC In Expert
hvacinexpert.com › home › daikin ac error codes list
Daikin AC Error Codes List
April 14, 2026 - Daikin is one of the most reliable ... solutions, you must confirm the error code properly. Turn on the AC. Press and hold the Cancel button for 5 seconds....
🌐
Parts Town
partstown.com › cm › resource-center › guides › gd2 › daikin-air-conditioner-fault-codes
Daikin Air Conditioner Fault Codes | Parts Town
Not certain what the flashing code on equipment means? Parts Town is here to help with some tips for Daikin air conditioner fault code troubleshooting.
🌐
JustAnswer
justanswer.com › hvac › mpcbg-installed-zone-daikin-mini-split-system-month.html
Daikin Mini Split A5 & UH Error Fix: Expert Q&A Guide
August 9, 2023 - For A5 errors, inspect indoor unit wiring connections and ensure the PCB is secure; clean or replace the indoor fan motor if noisy. UH errors indicate outdoor unit overheating—check for blocked condenser coils, dirty filters, or low refrigerant ...
🌐
ACIS
acsisair.com.au › home › blog › how to reset daikin aircon units
How to Reset Daikin Air Conditioner Units
September 14, 2023 - The inside reset button looks like a small red switch on the front of the unit. You can also find a reset button on the outside, which is ideal for use to reset Daikin aircon after a power outage.
🌐
Daikinairconditionerservice
daikinairconditionerservice.com.au › home › daikin air conditioner error codes
Daikin AC Error Codes: Full List, Meanings & Fixes 2026
1 week ago - If the code is A5 and the filter is visibly dirty, clean the filter before resetting. If the code is A3 and the drain pan is overflowing, empty it and attempt to clear the drain before resetting. If the code is E3 and the outdoor unit is surrounded by debris, clear the obstruction before resetting.
Price   $$
Call   +61370741838
Address   Melbourne, AU
🌐
Daikin India
daikinindia.com › product-services › product-services › error-codes
Error Codes | Daikin
Customer Support Information: WhatsApp us your query @ 9871409300. Call Our Customer Contact Centre: 011-40319300 / 1860 180 3900 or Write To Us at customerservice@daikinindia.com X