Daikin Sky Air VRV Mystery
UH and A5 error code daikin minisplits
Daikin AJ fault
When you get an aftermarket indoor unit PCB you need to get a capacity plug to set the capacity. The factory boards do not have them, so call back wherever you got the board and ask for the appropriate capacity plug.
Also, http://mobile.drdaikin.com
More on reddit.comDaikin mini split issue
Videos
I had 2 SkyAir systems installed last year that use the RZQ outdoor units paired with FTQ indoor air handlers. The systems worked amazingly at first & were super energy efficient. But the smaller unit now errors every few hours with a A6-20, CJ, or C4 error code. The larger system also errors once in a blue with same codes. My HVAC tech is stumped & even tried replacing the entire smaller system, but same issue. He did notice a very small amount of refrigerant disappears each trip. Anybody experience anything of the sort or have any idea what might be happening???