I have same error, did you fix the issue? (only on heat mode) Answer from t0lkman1421 on reddit.com
๐ŸŒ
Reddit
reddit.com โ€บ r/hvacadvice โ€บ daikin e3 error nightmare
r/hvacadvice on Reddit: Daikin E3 Error Nightmare
September 9, 2023 -

Ducted under floor residential system, 8 zone controller and 11 outlets. We have been having an E3 error for nearly a year: โ€œE3: Fault Code E3: Actuation of high pressure switch (HPS).โ€

The installation company has been very responsive, but have not fixed the issue even though they have replaced almost everything:

-control board -intake duct -high pressure switch -high pressure sensor -second intake was added to a different part of the house -completely drained and replaced refrigerant multiple times

The only common cause is when we have a cold night, not necessarily freezing cold but below 40 F / 5c. Doesnโ€™t seem to happen as frequently on mild nights.

Has anyone experienced something like this? What would be left to even replace? I am equally annoyed and curious to know what is actually causing it!

๐ŸŒ
Silverback Air-con
silverbackaircon.sg โ€บ home โ€บ aircon error code โ€บ daikin error code โ€บ daikin e3 error code (an ultimate guide)
Daikin E3 Error Code (An Ultimate Guide) - Silverback Air-con
February 23, 2024 - The Daikin E3 error code typically indicates either a high pressure switch or sensor defect or an instantaneous power failure. In both cases, clearing the E3 error entails replacing a malfunctioning PCB or thermistor, whichever is ultimately found to be the cause of the error.
Discussions

CNC Machining | Daikin Spindle Chiller Error Code E3 | Practical Machinist - Largest Manufacturing Technology Forum
Intermittently getting error code "E3" on a Daikin spindle chiller that came with our DMG Mori HMC. The machine is 8 years old. Daikin's website describes the error code: System No.1 Actuation of high pressure switch (HPS) Dirty outdoor unit heat exchanger Shortage of water volume Clogged... More on practicalmachinist.com
๐ŸŒ practicalmachinist.com
May 9, 2024
Code e3-01 on Daikin VRF unit
Having an issue with a Daikin VRF unit model# RXYQ120PBTJ. There is no operation from the unit, and the indoor thermostat is displaying an error code of E3-01. More on forum.heatinghelp.com
๐ŸŒ forum.heatinghelp.com
May 27, 2022
My Daikin brc1d52 constantly shows E3 error and shutdown, technician says i have to turn it off completely for 24h, so the auto-test resets, is it true ?
Looking it up the E3 code seems to be high pressure so that wouldn't even make sense if you were leaking refrigerant your outdoor coil Maybe dirty your fan could be dropping out but either way I don't think turning it off for 24 hours is going to make a difference More on reddit.com
๐ŸŒ r/hvacadvice
9
1
August 22, 2023
Daikin E3 Error Nightmare
I have same error, did you fix the issue? (only on heat mode) More on reddit.com
๐ŸŒ r/hvacadvice
16
3
September 9, 2023
๐ŸŒ
Errors Codes
errors.codes โ€บ inicio โ€บ daikin โ€บ air-conditioning โ€บ daikin air-conditioning - error e3
Solve the E3 error on your Daikin air conditioner
May 8, 2024 - However, like any electronic device, these units can experience errors in their operation and/or wear in their components and parts. The E3 error code in Daikin air conditioners indicates that there is a problem with the high-pressure switch, a ...
๐ŸŒ
JustAnswer
justanswer.com โ€บ hvac โ€บ rneh5-e3-error-code-daikin-unit-ap12891-year-filters.html
E3 Error Code on Daikin Unit? Reset Pump Help & Guide
After cleaning the filters on your ... the system to clear error codes. The E3 error typically indicates a water pump or drainage issue caused by clogged filters restricting flow....
๐ŸŒ
ACLogics
aclogics.com โ€บ hvac-diagnostics โ€บ daikin โ€บ e3-packaged
Daikin Error Code E3: Troubleshooting & Fixes - ACLogics
How to fix Daikin Packaged error code E3. Diagnosis: Actuation of high pressure switch (HPS). Causes: Dirty outdoor unit heat exchanger Defective high pressure switch Clogged refrigerant piping Defective connector contact.
Find elsewhere
๐ŸŒ
TechFaultFix
techfaultfix.com โ€บ home โ€บ heating & cooling (hvac) โ€บ air conditioners โ€บ daikin โ€บ e3
Daikin Air Conditioner - Error E3 - High-Pressure Protection
March 27, 2026 - Learn how to fix Daikin error code E3. Daikin system stops with E3; this may occur during cooling or heating under heavy load.. See common causes and step-by-step DIY repair instructions.
๐ŸŒ
Skycon Air Pty Ltd
skyconair.com.au โ€บ home โ€บ error codes โ€บ daikin error codes โ€บ e3
Daikin E3 Error Code
May 8, 2025 - The E3 error code indicates that the high-pressure sensor (HPS) has been triggered.
๐ŸŒ
JustAnswer
justanswer.com โ€บ hvac โ€บ qia9p-repair-strategies-hope-hvac.html
Fixing Daikin Mini-Split: E3 Error to Non-Functional Q&A
The E3 error on Daikin minisplits typically signals a refrigerant sensor or thermistor fault. Check the indoor unitโ€™s temperature sensor wiring for disconnections or corrosion. Inspect the outdoor unitโ€™s compressor for overheating or electrical ...
๐ŸŒ
Practical Machinist
practicalmachinist.com โ€บ forums โ€บ manufacturing today โ€บ cnc machining
CNC Machining | Daikin Spindle Chiller Error Code E3 | Practical Machinist - Largest Manufacturing Technology Forum
May 9, 2024 - Daikin's website describes the error code: Dirty outdoor unit heat exchanger Shortage of water volume Clogged refrigerant piping Defective connector contact Defective HPS ยท Click to expand... Spindle oil (Mobil Velocite No 3) was changed awhile back. It fixed this exact issue previously but ...
๐ŸŒ
Airway Group
airway-group.co.uk โ€บ home โ€บ help & advice โ€บ daikin air conditioning fault codes explained [infographic]
Daikin Air Conditioning Fault Codes Explained [Infographic] | Airway
April 2, 2026 - E3 โ€“ High pressure is too high (HPS activation) โ€“ The condenser may have short circuited or overloaded, or the heat exchanger may be dirty.
๐ŸŒ
ACLogics
aclogics.com โ€บ home โ€บ hvac error codes โ€บ daikin error codes โ€บ error code e3
Daikin Error Code E3 โ€” Dirty outdoor unit heat exchanger | Fix Guide
How to fix Daikin Split/ Multi Split error code E3. Diagnosis: Actuation of high pressure switch (HPS). Causes: Dirty outdoor unit heat exchanger Defective high pressure switch Clogged refrigerant piping Defective connector contact.
๐ŸŒ
Beaconsaves
beaconsaves.com โ€บ blog โ€บ daikin-mini-split-e3-error-code
Daikin Mini Split E3 Error Code: What It Means & What to Check | Beacon Services & Appliances
Q: What does the Daikin mini split error code E3 mean? A: On many Daikin mini split systems, E3 means high pressure protection. The outdoor side of the system is seeing pressure rise high enough that the unit protects itself and shuts down.
๐ŸŒ
Heating Help
forum.heatinghelp.com โ€บ a-c, heat pumps & refrigeration
Code e3-01 on Daikin VRF unit โ€” Heating Help: The Wall
May 27, 2022 - It turned out to be the inverter compressor was grounded. I went back today with a megger, and didnt need it because the compressor was grounded so bad a standard meter could pick it up. Strange that the same code could be a refrigerant, or electric issue
๐ŸŒ
JustAnswer
justanswer.com โ€บ uk-appliance โ€บ 7bs3w-daikin-units-showing-e3-error-code-high-pressure-switch-activated.html
How to Reset and Fix Daikin E3 Error Code | Expert Q&A
The E3 error on Daikin units indicates the high pressure switch has activated due to excessive refrigerant pressure. First, turn off the unit and check for blocked condenser coils or dirty filters restricting airflow.
๐ŸŒ
RemoveandReplace.com
removeandreplace.com โ€บ home โ€บ home air conditioning โ€บ daikin air conditioner ac error codes
DAIKIN Air Conditioner AC Error Codes
December 22, 2022 - Daikin AC Error Code = E3 Error Code Definition = Dirty outdoor unit heat exchanger What To Fix/Check/Replace = Actuation of high pressure switch โ€“ Shortage of water volume โ€“ Clogged refrigerant piping โ€“ Defective connector contact โ€“ ...
๐ŸŒ
JustAnswer
justanswer.com โ€บ hvac โ€บ lh9zb-daikin-hvac-model-dm96vc1005cn-propane-ran-out-propane.html
Daikin DM96VC1005CN Furnace Not Igniting? E3 Error Fix Guide
Error E3 on the DM96VC1005CN indicates ignition failure. After propane refill, check the igniter for cracks or wear. Inspect the flame sensor for dirt; clean it gently with fine sandpaper.
๐ŸŒ
JustAnswer
justanswer.com โ€บ hvac โ€บ phwi5-error-codes-daiken-unit-e1-e3-e4-e5-e6-e7-e8-e9.html
Daikin Unit Error Codes E1-E9: Troubleshooting Help Guide
July 10, 2024 - ... E1: Indoor unit communication error E3: Outdoor unit communication error E4: Compressor overcurrent protection E5: Compressor overheating protection E6: Low pressure protection E7: High pressure protection E8: Outdoor unit sensor error E9: ...
๐ŸŒ
Daikin NZ
daikin.co.nz โ€บ blogs โ€บ knowledge-base โ€บ what-is-a-e3-fault
What is a E3 fault? โ€“ Daikin NZ
February 24, 2025 - Fault E3 is Abnormal high pressure (detected by high pressure switch) For more information open the Daikin Service App on your mobile. 1. Ensure you are logged into the Daikin Service App.