Daikin
my.daikin.eu › content › dam › DASW › supportavdelningen › Felkoder_SM-TS3errorcode_chart.pdf pdf
Simple Self-Diagnosis by Malfunction Code After Sales Service Division (SM-TS3)
“long beep” sound are error code. 8. Press the MODE button to exit from the · diagnosis mode. The display “ ” means the trial operation · mode. 9. Press the ON/OFF button twice to return · to the normal mode. Note: When the remote controller is left untouched · for 60 seconds, it returns to the normal mode. No. 1 · 2 · 3 · 4 · 5 · 6 · 7 · 8 · 9 · 10 · 11 · Code · 00 · U4 · F3 · E6 · L5 · A6 · E5 · F6 · C9 · U0 · E7 · No. 12 · 13 · 14 ·
🌐
Blossomaircon
blossomaircon.com › daikin-aircon-error-code-u0
Daikin Aircon Error Code U0: Causes and Solutions – BLOSSOM AIR-CON
May 27, 2025 - Error code U0 in your Daikin AC indicates that the system has detected a shortage of refrigerant. As we know that refrigerant gas is essential for the cooling process. It circulates throughout the system and keep the heat exchange process running.
Discussions

Daikin Mini split keeps shutting off. Error code U0
Lmao. U0 is the code for low refrigerant. Tell your “maintenance person” to promptly fuck right off, hire a proper licensed tech and get the leak repaired. More on reddit.com
🌐 r/hvacadvice
15
1
July 27, 2025
Daikin U0 error code my tech and I have tried everything
Following because our tech can’t figure out our U0 error code either. We get the code every 2 days right now. Our tech told us to cut the power by flipping the circuit breaker for 30 seconds then flip it back on. That temporarily fixes it but I’d like a real solution. Getting up in the middle of the night to do this is tiresome. More on reddit.com
🌐 r/hvacadvice
2
3
January 26, 2025
Daikin 7j-/071 error u0 - low on refrigerant during winter?
Hi! Contact your HVAC installer. This could be faulty machine from Daikin. They are aware of these and have already contacted the suppliers. Did you by any chance recently connect your device into Onecta mobile app? More on reddit.com
🌐 r/hvacadvice
5
1
December 23, 2024
Does this look like a refrigerant leak? Chasing down error code U0 on Daikin Mini-Split FTXS24LVJU/RXS24LVJU.
That just looks like dirty lines, but the leak could be at the indoor flares. More on reddit.com
🌐 r/hvacadvice
6
0
July 7, 2021
People also ask

Does U0 definitely mean a refrigerant leak?
Most of the time it points that direction, but a full diagnosis should still confirm the exact reason the system sees a shortage condition.
🌐
beaconsaves.com
beaconsaves.com › blog › daikin-mini-split-u0-error-code
Daikin Mini Split U0 Error Code: What It Means & What to Check ...
Will adding refrigerant fix U0 permanently?
Only if the reason for the loss is corrected first. If there is a leak, the code will come back.
🌐
beaconsaves.com
beaconsaves.com › blog › daikin-mini-split-u0-error-code
Daikin Mini Split U0 Error Code: What It Means & What to Check ...
Can I keep running the system with U0?
It is better not to. Low-charge operation can reduce comfort and may stress the compressor.
🌐
beaconsaves.com
beaconsaves.com › blog › daikin-mini-split-u0-error-code
Daikin Mini Split U0 Error Code: What It Means & What to Check ...
🌐
Daikin
daikin.com › products › ac › services › error_codes
Error Codes | After Sales Service | Air Conditioning and Refrigeration | Daikin Global
Error Code Search offers information on the cause of the malfunction and the status of your air conditioner by entering the error code.
🌐
Daikin India
daikinindia.com › product-services › product-services › error-codes
Error Codes | Daikin
Customer Support Information: WhatsApp us your query @ 9871409300. Call Our Customer Contact Centre: 011-40319300 / 1860 180 3900 or Write To Us at customerservice@daikinindia.com X
🌐
Daikin
daikin.com › - › media › Project › Daikin › daikin_com › products › ac › services › error_codes › pdf › sm-ts3_p7-8_howtocheck-pdf.pdf pdf
UNIT NO. 1 CODE UNIT NO. 1 3. Press MODE selector button. 4. Change the
“long beep” sound are error code. 8. Press the MODE button to exit from the · diagnosis mode. The display “ ” means the trial operation · mode. 9. Press the ON/OFF button twice to return · to the normal mode. Note: When the remote controller is left untouched · for 60 seconds, it returns to the normal mode. No. 1 · 2 · 3 · 4 · 5 · 6 · 7 · 8 · 9 · 10 · 11 · Code · 00 · U4 · F3 · E6 · L5 · A6 · E5 · F6 · C9 · U0 · E7 · No. 12 · 13 · 14 ...
🌐
Fixurge LLC
fixurge.com › home › daikin › daikin u0 error code: causes, fixes, and how to repair it
Daikin U0 Error Code: Causes, Fixes, and Repair Cost
April 22, 2026 - Daikin U0 error means low refrigerant. Learn causes, symptoms, repair costs, and when to call HVAC professionals.
Address   1055 Wilshire Blvd. Suite 900-B, 90017, Los Angeles
Find elsewhere
🌐
Daikin ONE
daikinone.com › smart_thermostats › oneplus › pros › PhaseTwoErrorCodes.pdf pdf
Climate Talk Fault Code Dealer error code Possible causes Corrective actions
•Call Daikin support at 1-855-DAIKIN1(option1) Thermostat · minor · Internal hardware error · 14 · 0F · Wi-Fi hardware error · WIFI driver communication issue. •Check for proper 24 VAC powering thermostat. •Conduct a warm start of the thermostat. •Call Daikin support at ...
🌐
JustAnswer
justanswer.com › hvac › l00sp-daikin-support-working-daikin-4mxs36rmvjua-heat.html
Daikin Heat Pump Troubleshooting: U0 Code Fix Guide
You are right; U0 indicates low refrigerant levels. There must be a leak present. It's essential to inspect all your connections. Simply topping off the refrigerant is not beneficial for the system.
🌐
Reddit
reddit.com › r/hvacadvice › daikin mini split keeps shutting off. error code u0
r/hvacadvice on Reddit: Daikin Mini split keeps shutting off. Error code U0
July 27, 2025 -

We had 3 mini splits installed in our home 5 years ago. After about 2 years, they started showing error code U0, repair person came, found a leak and fixed it.
Now, 2 years later, the 3 units keep shutting off every couple of hours and showing U0 code again. If we flip the breaker, they will work for a few hours then shut off again.
Another maintenance person came last week and said the pressure looked good and it's blowing cold so he didn't expect there was a leak. After a bunch of wandering around and not really taking anything apart, he concluded that there was reduced airflow because there was some dust inside the unit (not the filters that you can take out--those were clean). He said we would need to pay for a maintenance package if we wanted someone to come clean out the units to resolve the problem even though they are under warranty until 2030.
Any ideas what else it could be as I've read that this code could be caused by a faulty valve, compressor etc too.

🌐
JustAnswer
justanswer.com › hvac › mh5am-i-m-getting-error-code-u0-not-sure-when-moved.html
How to Fix Daikin Error Code U0: Expert Solutions and Advice
July 13, 2023 - The U0 error code typically indicates a sensor or control board communication issue. Start by unplugging the appliance for 5 minutes to reset the control board. Check wiring connections to sensors for looseness or corrosion.
🌐
HVAC Toolkit
hvactoolkit.org › home › resources › error codes › daikin
Daikin Error Codes - Complete Fault Code List & Solutions | HVAC Toolkit
Complete Daikin error code list for mini-splits, VRV systems, and air conditioners. Find meanings, causes, and troubleshooting solutions for all Daikin fault codes.
🌐
RemoveandReplace.com
removeandreplace.com › home › home air conditioning › daikin air conditioner ac error codes
DAIKIN Air Conditioner AC Error Codes
December 22, 2022 - Huma, Daikin AC “U0” = Low pressure drop due to refrigerant shortage or electronic expansion valve failure. According to the DAIKIN operation manual your system is low on refrigerant. You will need to charge your unit and find the leak.
🌐
Airway Group
airway-group.co.uk › home › help & advice › daikin air conditioning fault codes explained [infographic]
Daikin Air Conditioning Fault Codes Explained [Infographic] | Airway
April 2, 2026 - U0 – Suction pipe temperature is too high – A fault with the refrigerant piping system – either clogging or a lack of refrigerant, or there may be a fault with the expansion valve.
🌐
Star-supply
star-supply.com › content › Daikin-Troubleshooting Codes.pdf pdf
Trouble Shooting www.climatecenter.co.uk Daikin Trouble Shooting Guide
Capacity setting error · Incorrect capacity setting · • · • · Trouble Shooting · www.climatecenter.co.uk · Daikin Trouble Shooting Guide · Past & Current Models · Daikin Fault Codes · System Fault Codes · Fault Code · Definition · Supposed Causes · Split · Skyair · VRV · ...
🌐
TechFaultFix
techfaultfix.com › home › heating & cooling (hvac) › air conditioners › daikin › u0
Daikin Air Conditioner - Error U0 - Refrigerant Shortage / Undercharge Protection
March 27, 2026 - Clean the indoor and outdoor coils with a soft brush to ensure the error is not due to airflow restriction causing abnormal pressures. ... Recover remaining refrigerant and perform a nitrogen pressure test and soap-bubble or electronic leak detection on all joints, coils, and service valves. Repair or replace leaking components (flare joints, piping, indoor or outdoor heat exchanger). Evacuate the system to proper vacuum and recharge with the exact Daikin-specified refrigerant type and weight from the nameplate.
🌐
CoolAutomation
coolautomation.com › blog › daikin error codes: comprehensive breakdown
Daikin Error Codes (Malfunction Self-Diagnosis)
July 20, 2025 - Easily identify Daikin HVAC system faults with this complete list for simple self-diagnosis & troubleshooting. Includes VRV, SkyAir, HRV systems, and more.
🌐
Silverback Air-con
silverbackaircon.sg › home › articles › daikin error codes and how much it costs to fix
Daikin Error Codes and How Much It Costs to Fix - Silverback Air-con
April 20, 2026 - Although we are not able to fully explain all of the error codes in this article, let us elaborate on some of the most common error codes here. U0 indicates that your refrigerant is empty.
🌐
Atlas Aircon
atlasaircons.com › fault-codes › daikin-ac-error-code-u0
🔴 Daikin AC Error Code U0 Fixed | Official Troubleshooting & Repair | Atlas Aircon
February 8, 2026 - ... The U0 Error is Daikin’s specific code for “Gas Shortage.” The Electronic Expansion Valve (EEV) opens fully to let gas flow, but the thermistors don’t detect any temperature drop.
🌐
Penair
penair.com.au › home › how to reset a daikin air conditioner
Daikin Troubleshooting: Error Codes & Resetting A Daikin
November 10, 2025 - Master Daikin troubleshooting with our updated 2024 guide. Reset your air conditioner and solve common issues easily.