They have their own specific setup that I can’t remember (too many schematics in my brain). If it runs for a little bit and then shuts off for a while, kicks on for a bit and yada yada, check your condensate line, might be tripping a “safety switch.” Thats a quick fix, vacuum out the line. Check around the condenser and see if there’s a bunch of droppings. Rodents like to keep warm and chew on wires, those little bastards. Could be a number of things. But I’d start with the condy line. Answer from Deleted User on reddit.com
🌐
Reddit
reddit.com › r/hvacadvice › [daikin vrv] [220 vac] u4-01 error code help
r/hvacadvice on Reddit: [Daikin VRV] [220 VAC] U4-01 Error Code Help
September 6, 2024 -

My air conditioning failed on me some time today when I was at work, and when I returned home it was 92° inside my home. Figures this would happen during the (hopefully) hottest week of the year in Los Angeles. This system was professionally installed in June of 2020, and has worked without issue until now. The company that did it was bought out by another larger firm, and they are unable to send a tech out for another 17 days. I’m kind of SOL there. I change the filters every six months in the air handlers, and regularly hose down/clean the exterior unit. With a basic visual inspection, it does not appear that there are any blockages/impediments to air flow. I have tried powering off both the exterior unit and both interior air handlers by switching off the breakers on two separate occasions. The cooling works for about 10 minutes and then the error message is displayed again on the interior control panel. Any ideas?

🌐
JustAnswer
justanswer.com › hvac › kv8uf-daikin-support-air-con-heater-error-code-u4-01.html
Daikin U4-01 Error Code? Troubleshooting Help & Fix Guide
December 22, 2022 - The U4-01 error on Daikin units typically indicates a temperature sensor or communication fault. First, power off the unit and check sensor wiring connections for looseness or damage.
Discussions

Waarschuwingscode: U4-00 Daikin. There is communication
Waarschuwingscode: U4-00 Daikin. There is communication problem so he says in de insite unit. Half test ago. Half year More on justanswer.com
🌐 justanswer.com
1
August 24, 2024
I have a Daikins inverter that is giving a U4 error code. I
I have a Daikins inverter that is giving a U4 error code. I turned off the power, let stand 5 min, restarted and it More on justanswer.com
🌐 justanswer.com
1
August 3, 2024
Daikin Mini split- error code U4
There’s a specific process to it. Need a Daikin d checker tool to really further diagnose More on reddit.com
🌐 r/hvacadvice
7
2
November 25, 2023
[Daikin VRV] [220 VAC] U4-01 Error Code Help
They have their own specific setup that I can’t remember (too many schematics in my brain). If it runs for a little bit and then shuts off for a while, kicks on for a bit and yada yada, check your condensate line, might be tripping a “safety switch.” Thats a quick fix, vacuum out the line. Check around the condenser and see if there’s a bunch of droppings. Rodents like to keep warm and chew on wires, those little bastards. Could be a number of things. But I’d start with the condy line. More on reddit.com
🌐 r/hvacadvice
6
4
September 6, 2024
🌐
Whirlpool
forums.whirlpool.net.au › home › air con › daikin error code: u1-04
Daikin error code: U1-04 - Air conditioners
Error Code:U1-04 · sounds like you had a phase drop, If the reboot dont work , Could of fried a PCB ? User #101110 3582 posts · bigal99 · Whirlpool Forums Addict · reference: whrl.pl/RdDR4D · posted 2013-Jul-7, 5:43 pm AEST · ref: whrl.pl/RdDR4D · posted 2013-Jul-7, 5:43 pm AEST · d angel writes... We lost power in our house (street? it's been pretty windy) earlier this morning and our Daikin aircon/heating system didn't like it.
🌐
JustAnswer
justanswer.com › hvac › c107x-fault-code-u4-u0-two-head-units.html
Daikin Error Code U0-04 & U0: Expert Solutions | JustAnswer HVAC
February 6, 2019 - Fault codes U4 and U0 typically indicate communication errors between the indoor head units and the outdoor condenser. Check wiring connections for loose or damaged cables linking the two head units to the condenser.
🌐
JustAnswer
justanswer.com › hvac › bvmqb-u4-error-daikin-indoor-unit-keeps.html
Daikin U4 Error Code: Expert Solutions and Fixes
December 27, 2018 - The U4 error on Daikin units often indicates a fan motor or flap actuator malfunction. First, power off and vacuum dust from the indoor unit’s fan and flap mechanisms. Check for obstructions preventing flap movement.
🌐
Daikin
daikin.com › products › ac › services › error_codes
Error Codes | After Sales Service | Air Conditioning and Refrigeration | Daikin Global
Error Code Search offers information on the cause of the malfunction and the status of your air conditioner by entering the error code.
🌐
Star-supply
star-supply.com › content › Daikin Single- Multi -U4 Error Code.pdf pdf
Daikin Single-Multi U4 Error Codes
Only good for Daikin Single Zones & Multi-Splits-NOT VALID ON VRV OR SKYAIR · U4 Fault code is a Signal Transmission Error (between Indoor Unit and Outdoor Unit)
Find elsewhere
🌐
JustAnswer
justanswer.com › hvac › pvzz2-waarschuwingscode-u4-00-daikin-communication.html
Daikin U4-00 Warning Code? Expert Troubleshooting Guide
August 24, 2024 - The Daikin U4-00 error code signifies a communication issue between the indoor and outdoor units of your Daikin HVAC system, indicating that the signal between these units has been disrupted or lost.
🌐
Airway Group
airway-group.co.uk › home › help & advice › daikin air conditioning fault codes explained [infographic]
Daikin Air Conditioning Fault Codes Explained [Infographic] | Airway
April 2, 2026 - U1 – Reverse phase – The three phase power supply has been reversed. U2 – Open phase or power voltage imbalance – There may be an open phase or a voltage imbalance in the power supply.
🌐
Scribd
scribd.com › document › 425197901 › Daikin-error-code-pdf
Daikin VRV Error Code Troubleshooting Guide | PDF | Manufactured Goods | Electrical Engineering
U1 − 01 Reverse phase/open phase for power supply (Master) U1 − 04 Reverse phase for power supply [with power supply turned ON] (Master) U1 − 05 Reverse phase/open phase for power supply (Slave 1) Refer to the “U1” flow chart of each ...
Rating: 5 ​ - ​ 1 votes
🌐
JustAnswer
justanswer.com › hvac › pphzc-daikins-inverter-giving-u4-error-code.html
Daikin Inverter U4 Error Code? Expert Troubleshooting Guide
August 3, 2024 - The U4 error on a Daikin inverter typically indicates a communication or sensor fault. First, power off the unit for 5 minutes to reset. If persistent, check the indoor unit’s PCB connections and wiring harness for loose or damaged cables.
🌐
Reddit
reddit.com › r/hvacadvice › daikin mini split- error code u4
r/hvacadvice on Reddit: Daikin Mini split- error code U4
November 25, 2023 -

I’m a little lost on trying to trouble shoot this one, any advice is appreciated. I purchased a 2 ton single head Daikin minisplit system online a few months ago to install in a workshop in my backyard, that I’m in the process of renovating. Everything was going smoothly with the install, doing the majority of the work myself. I am a builder by trade and have done several minisplit installs over the years. I hired an HVAC tech to connect the refrigerant linesets, and evacuate/ pressure test the lines. As far as I can tell the problem came about when I connected the wiring. Unfortunately I crossed the signal line and one of the power lines at the outdoor unit control wiring. When I went to fire up the system, the indoor unit status light started flashing blue, indicating a system error. I realized what had happened then and corrected the wiring. No luck, still flashing blue. Error code retrieval at this point, at the remote control reads U4: communication error. Next I tried pulling the outdoor unit control panel to see if there is a blown fuse. I was able to locate 3 separate fuses but none of them tested bad. Pulled the indoor unit control board and there is one fuse which also checked out ok. Last I try running a separate jumper wire externally to eliminate the possibility that there is an unseen break in the original signal wire. I then try turning the system on again, same thing: indoor unit status light flashing blue and error code U4. Any ideas?

🌐
ADK Kooling
adk.co.uk › home › air conditioning › daikin error code u4 — vrv communication fault explained
Daikin Error Code U4 | Communication Fault Fix | ADK London
March 23, 2026 - Daikin VRV showing U4 error code? It's a communication fault between indoor and outdoor units. Common causes and fixes explained. Call ADK London.
Price   $$
Address   Daneshill House, 3 Waterloo Road, UB8 2QX, Uxbridge
🌐
Star-supply
star-supply.com › content › Daikin-Troubleshooting Codes.pdf pdf
Trouble Shooting www.climatecenter.co.uk Daikin Trouble Shooting Guide
Capacity setting error · Incorrect capacity setting · • · • · Trouble Shooting · www.climatecenter.co.uk · Daikin Trouble Shooting Guide · Past & Current Models · Daikin Fault Codes · System Fault Codes · Fault Code · Definition · Supposed Causes · Split · Skyair · VRV · Package · HRV · U0 · Shortage of refrigerant ...
🌐
Arlington Air Conditioning Services
arlingtonairconditioningheating.com › arlington hvac audit › air conditioner error codes › 99 daikin aircon error codes + troubleshooting
Daikin AC Error Codes & Troubleshooting (2026 Interactive Decoder)
April 21, 2026 - Whether you are dealing with a low refrigerant warning (U0), a communication failure between the indoor and outdoor units (U4), or an inverter compressor overcurrent (L5), decoding these Daikin faults quickly can save you from unnecessary panic and expensive service calls.
🌐
RemoveandReplace.com
removeandreplace.com › home › home air conditioning › daikin air conditioner ac error codes
DAIKIN Air Conditioner AC Error Codes
December 22, 2022 - U0 System Shortage of refrigerant or EEV failure U1 System Negative phase, Open phase U2 System Power supply insufficient U3 System Wiring check operation not executed U3 System Mismatch of indoor and outdoor units – Split only U4 System ...
🌐
CoolAutomation
coolautomation.com › blog › daikin error codes: comprehensive breakdown
Daikin Error Codes (Malfunction Self-Diagnosis)
July 20, 2025 - Following are some of the most common Daikin error codes and their presumed causes. Tired of wasting time with repeated on-site visits, finally diagnosing a problem, and then realizing you lack the necessary parts?
🌐
AirReps
airreps.com › 2025 › 11 › understanding-the-u4-error-code-in-daikin-vrv-systems
Understanding the U4 Error Code in Daikin VRV Systems - AirReps
November 19, 2025 - The U4 error code signals that your Daikin VRV system needs professional attention for a communication problem. While it’s frustrating to see your system shut down, this error code is actually protecting your equipment from operating incorrectly.
🌐
Daikin
my.daikin.eu › content › dam › DASW › supportavdelningen › Felkoder_SM-TS3errorcode_chart.pdf pdf
Simple Self-Diagnosis by Malfunction Code After Sales Service Division (SM-TS3)
U1 · Reverse phase, open phase · Power supply reverse phase · T phase open phase · Defective outdoor unit PCB (A1P) k k k k k k k · U2 · Malfunction of power supply or · instantaneous power failure · Abnormal power supply voltage · Instantaneous power failure · Defective main circuit ...