Reddit
reddit.com › r/hvac › daikin hvac f3 fault code advice
r/HVAC on Reddit: Daikin HVAC F3 Fault Code Advice
April 13, 2018 -

Hello guys!

My Daikin heating & cooling system recently stopped working and the solid green light turned into a blinking green light. With some quick googling, I found a video on how to diagnose the HVAC system and find the fault code using the remote control.

After scrolling through the codes, there was a solid long beep on F3, indicating that that's the fault. According to https://www.daikin.com/products/ac/services/error_codes/pdf/sm-ts3_p1-6_errorcode.pdf, the F3 fault code indicates a "Malfunction of discharge pipe temperature".

After getting quotes from different HVAC repair businesses in my area, I quickly found out that the prices are in the hundreds of dollars just to come out and diagnose the problem. Then perhaps weeks for the parts to get in if there was a special parts needed.

Which brings me to the reddit /HVAC community. I was wondering if any of you guys know if there was a guide on how to fix the F3 error code myself, or if it's best for me to just shell out the hundred of dollars for a trained technician to come out and attempt to fix it.

Thank you in advance for your help!

🌐
Daikin
daikin.com › - › media › Project › Daikin › daikin_com › products › ac › services › error_codes › pdf › sm-ts3_p1-6_errorcode-pdf.pdf pdf
Simple Self-Diagnosis by Malfunction Code After Sales Service Division (SM-TS3)
F3 · Malfunction of discharge pipe · temperature · Defective discharge pipe thermistor · Abnormal discharge pipe temperature · Defective outdoor unit control PCB · Defective connector contact · k k k k · k · F6 · Abnormal high pressure or · refrigerant overcharged ·
Discussions

I have a Daikin heat pump and there is an f3 malfunction of
I did some research and found a general malfunction code for the Daikin units. The error is simply telling us that the discharge pipe temperature is abnormal. You can try turning power off and back on to see if it will reset. If it does not we're going to need a set of refrigerant gauges to troubleshoot this. ... The error can be caused by refrigerant charge issue or the defective sensor. To troubleshoot this you want to put your refrigerant gauges on it and test the pressures. ... F3 ... More on justanswer.co.uk
🌐 justanswer.co.uk
1
February 25, 2023
Daikin HVAC F3 Fault Code Advice
Almost sounds like you tripped your high limit. Plenum got too hot. When was the last time you changed your filter? More on reddit.com
🌐 r/HVAC
12
4
April 13, 2018
Help with Daikin error code F3

Hi all,

Just after a bit of guidance with what may be the issued with our unit. I'm getting error code F3. When in heat mode no air will come out, and after a few mintues the power light will flash and the remote will give error code F3. When in cool mode it will blow air indefinitely from what I can tell but it is just room temperature air, it is not cold air. For the 1st couple of hours while in cool mode the outdoor unit doesn't do anything, fan doesn't spin up, the fins don't appear to get hot either. After a couple of hours the fan spins very slowly. Just quick enough to pull air though but bairly audible, still slow enough to see the individual fan blades.

Model is Daikin FTXM25QVMA, I have posted pics of the model tags of the indoor and outdoor units.

Other notable info: There may be an ants nest in the indoor unit, the wife and I have noticed a lot of dead ants on the bench below the unit each time we put ant baits out.

Other notable info 2: 6 months ago the unit was repaired under warranty after having error code 00. It did not turn on at all, cool or hot. The repairman replaced the coils in the indoor unit and it worked fine for at least 3-4 months (we didn't use it until now so hard to tell). It is no longer under warranty and Daikin are not willing to come out again without charging (fair enough).

Anything else I think of I'll edit this post. A bit of guidance as to what may be the cause would be appreciated so much.

More on reddit.com
🌐 r/hvacadvice
4
1
June 15, 2023
Daikin heat pump giving F3 error code. Okay to reset and use?
Could have been multiple leaks. Needs to be pressure tested. Also with mini splits the proper way to charge a system is recover all refrigerant and weigh in proper charge per manufacturer More on reddit.com
🌐 r/HVAC
3
0
December 24, 2019
🌐
JustAnswer
justanswer.com › hvac › 330vu-daikin-heat-pump-going-off-f3-error-code-high-discharge.html
Daikin F3 Error Code: Expert Solutions and Fixes
January 31, 2010 - The F3 error on a Daikin heat pump indicates high discharge temperature, often caused by restricted airflow or refrigerant issues. Check and clean air filters and outdoor coils to improve airflow.
🌐
Aivon
aivon.com › home › blog › industrial control › diagnosing air conditioner f3 fault code
Diagnosing Air Conditioner F3 Fault Code
February 10, 2026 - This indicates the F3 fault was caused by reduced airflow from the stopped fan, leading to inadequate heat dissipation, elevated discharge pipe temperature, and a protective shutdown with F3 code.
🌐
Skycon Air Pty Ltd
skyconair.com.au › home › error codes › daikin error codes › f3
Daikin F3 Error Code
May 9, 2025 - The F3 error code indicates a malfunction of the discharge pipe temperature sensor.
🌐
Airintelligence
airintelligence.com › news › files › 2021-03 › tsb-ot-0008-19-series-18000-and-24000-btu-heat-pumps-f3-error-code-final.pdf pdf
Airintelligence
An F3 error code indicates a low refrigerant · charge or high discharge pipe temperature and shuts down the unit in heating mode. ... Daikin engineers have identified the root cause of this condition and are currently placing a phased
🌐
Scribd
scribd.com › document › 682303889 › Error-Code-f3-Daikin-Google-Search
Understanding Daikin F3 Error Code | PDF | Air Conditioning | Building Engineering
The error code F3 on Daikin air conditioners indicates a high discharge temperature, which is usually caused by insufficient refrigerant, a clogged refrigerant piping, or a faulty discharge temperature thermistor.
🌐
Silverback Air-con
silverbackaircon.sg › home › aircon error code › daikin error code › daikin f3 error code (an ultimate guide)
Daikin F3 Error Code (An Ultimate Guide) - Silverback Air-con
November 17, 2025 - A Daikin F3 error code simply refers to malfunctioning of the discharge pipe thermistor. In fact, you can even find the description of this in the Daikin error code list. So what does it mean by this? A Daikin condenser unit normally has a few thermistor. And one of them is the discharge pipe ...
Find elsewhere
🌐
JustAnswer
justanswer.com › hvac › o1jbz-want-know-error-code-f3-means-soleus-air.html
Understanding Error Code F3 in Soleus Air and Daikin AC Units
The F3 error on Soleus Air and Heat split window units typically indicates a temperature sensor malfunction or a communication error between the indoor and outdoor units. First, reset the system by powering off for several minutes.
🌐
Airway Group
airway-group.co.uk › home › help & advice › daikin air conditioning fault codes explained [infographic]
Daikin Air Conditioning Fault Codes Explained [Infographic] | Airway
April 2, 2026 - F3 – Outdoor unit discharge temperature is too high – Insufficient refrigerant, clogged refrigerant piping or the discharge temperature thermistor could be faulty.
🌐
JustAnswer
justanswer.co.uk › hvac › lcjs3-daikin-heat-pump-f3-malfunction.html
I have a Daikin heat pump and there is an f3 malfunction of discharge pipe temperature error on indoor unit. Can I power
February 25, 2023 - The F3 error on a Daikin heat pump indicates a discharge pipe temperature sensor fault. First, power off the system using the main switch or circuit breaker, then power it back on to attempt a reset.
🌐
YouTube
youtube.com › watch
How to Fix F3 Error in Daikin AC – Meaning, Causes & Step-by-Step Troubleshooting Guide - YouTube
In this troubleshooting video, learn how to diagnose and fix the F3 error code on your Daikin air conditioner (AC). The F3 error typically indicates a proble...
Published   July 16, 2024
🌐
ErrBase
errbase.com › home › daikin › minisplit › f3 error
Daikin F3 Error Code: High Discharge Pipe Temperature | ErrBase
Daikin F3 error means your compressor is overheating. Senior tech explains how to test the discharge thermistor and why low refrigerant is the main cause.
🌐
Star-supply
star-supply.com › content › Daikin-Troubleshooting Codes.pdf pdf
Trouble Shooting www.climatecenter.co.uk Daikin Trouble Shooting Guide
Daikin Trouble Shooting Guide · Past & Current Models · No. Code · No. Code · No. Code · 1 · 00 · 11 · E7 · 21 · UA · 2 · U4 · 12 · C7 · 22 · A5 · 3 · F3 · 13 · H8 · 23 · J9 · 4 · E6 · 14 · J8 · 24 · E8 · 5 · L5 · 15 · A3 · 25 ·
🌐
RemoveandReplace.com
removeandreplace.com › home › home air conditioning › daikin air conditioner ac error codes
DAIKIN Air Conditioner AC Error Codes
December 22, 2022 - Daikin AC Error Code = F3 Error Code Definition = Malfunction of discharge pipe temperature – Defective discharge pipe thermistor – Abnormal discharge pipe temperature What To Fix/Check/Replace = Defective outdoor unit control PCB – Defective ...
🌐
TechFaultFix
techfaultfix.com › home › heating & cooling (hvac) › air conditioners › daikin › f3
Daikin Air Conditioner - Error F3 - Discharge Pipe Temperature High
March 27, 2026 - Learn how to fix Daikin error code F3. Daikin system stops with F3, often in heating mode.. See common causes and step-by-step DIY repair instructions.
🌐
Daikin
daikin.com › products › ac › services › error_codes
Error Codes | After Sales Service | Air Conditioning and Refrigeration | Daikin Global
Error Code Search offers information on the cause of the malfunction and the status of your air conditioner by entering the error code. Error Code Search List of Error Codes(0.1MB) Please refer to "How to Check Error Codes" for step-by-step instruction to check the error codes.
🌐
Mytour
mytour.vn › home › travel › troubleshooting daikin ac error code f3: causes and solutions
Daikin Air Conditioner Error Code F3: Causes and Solutions | Mytour.vn
November 6, 2024 - To troubleshoot the F3 error code on your Daikin AC, first check for low refrigerant levels and recharge if necessary. Inspect and replace a faulty expansion valve, clear any blockages in the refrigerant lines, and ensure the push tube temperature sensor is functioning correctly.
🌐
Snowflakeaircon
snowflakeaircon.sg › home › error code lookup › daikin error codes › f3
Daikin F3 error code: pressure & leak checks
May 21, 2026 - Daikin F3 is listed as high temperature discharge pipe control and malfunction of discharge pipe temperature in Inverter Split, Multi-Split, Ceiling Cassette rows such as EZi, iSmart ENVi. The loaded row is source-backed by official diagnostic material. Do not collapse this code across model ...
🌐
Airchillac
airchillac.com › daikin-ac-error-codes
Daikin AC Error Codes Guide – Fixes, and Troubleshooting Tips | AirChill AC Maintenance and Duct Cleaning
June 5, 2025 - F3 – High discharge temperature · H0 – Protection mode turned on · U0 – Low gas (refrigerant) U2 – Problem with power supply · U4 – Indoor and outdoor units are not talking to each other · UA – Units do not match (indoor/outdoor) ...