Reddit
reddit.com › r/hvac › daikin hvac f3 fault code advice
r/HVAC on Reddit: Daikin HVAC F3 Fault Code Advice
April 13, 2018 -

Hello guys!

My Daikin heating & cooling system recently stopped working and the solid green light turned into a blinking green light. With some quick googling, I found a video on how to diagnose the HVAC system and find the fault code using the remote control.

After scrolling through the codes, there was a solid long beep on F3, indicating that that's the fault. According to https://www.daikin.com/products/ac/services/error_codes/pdf/sm-ts3_p1-6_errorcode.pdf, the F3 fault code indicates a "Malfunction of discharge pipe temperature".

After getting quotes from different HVAC repair businesses in my area, I quickly found out that the prices are in the hundreds of dollars just to come out and diagnose the problem. Then perhaps weeks for the parts to get in if there was a special parts needed.

Which brings me to the reddit /HVAC community. I was wondering if any of you guys know if there was a guide on how to fix the F3 error code myself, or if it's best for me to just shell out the hundred of dollars for a trained technician to come out and attempt to fix it.

Thank you in advance for your help!

🌐
Reddit
reddit.com › r/hvac › daikin heat pump giving f3 error code. okay to reset and use?
r/HVAC on Reddit: Daikin heat pump giving F3 error code. Okay to reset and use?
December 23, 2019 -

The error is "Malfunction of discharge pipe temperature". We had someone come out to look at it and they said there was a refrigerant leak. They fixed the leak, refilled refrigerant and left.

Now 9 days later the same thing happens. It started putting out very little heat, then just gave up and shuts off and starts blinking.

I shut the power off to it and turned it back on and it's been working well for the past 48 hours. I asked them to come out to fix it, but no one is available till the 26th, three days from now and 5 days since I power cycled it.

So is it ok to continue using it if it's working well? And is this normal? I live in new england, the house we bought only had baseboard electric heat, and we spent a lot of money to install the heatpump to heat the whole house, and I'm feeling a little upset about the recent lack of reliability and no ones ability to get out to fix it on time.

🌐
Daikin
daikin.com › - › media › Project › Daikin › daikin_com › products › ac › services › error_codes › pdf › sm-ts3_p1-6_errorcode-pdf.pdf pdf
Simple Self-Diagnosis by Malfunction Code After Sales Service Division (SM-TS3)
F3 · Malfunction of discharge pipe · temperature · Defective discharge pipe thermistor · Abnormal discharge pipe temperature · Defective outdoor unit control PCB · Defective connector contact · k k k k · k · F6 · Abnormal high pressure or · refrigerant overcharged ·
🌐
Daikin
daikin.com › products › ac › services › error_codes
Error Codes | After Sales Service | Air Conditioning and Refrigeration | Daikin Global
Error Code Search offers information on the cause of the malfunction and the status of your air conditioner by entering the error code.
🌐
Airintelligence
airintelligence.com › news › files › 2021-03 › tsb-ot-0008-19-series-18000-and-24000-btu-heat-pumps-f3-error-code-final.pdf pdf
Airintelligence
February 15, 2021 - ... Daikin engineers have identified ... a permanent solution. Interim resolution: For units already installed, if the unit does shut down, recycling the power to the · unit will reset the error code and the unit will continue to run until the event repeats itself....
🌐
Snowflakeaircon
snowflakeaircon.sg › home › error code lookup › daikin error codes › f3
Daikin F3 error code: pressure & leak checks
May 21, 2026 - Capture the F3 display, then power-cycle once only if the unit is not icing, leaking, or tripping. Do not use reset as a gas or pressure fix. F3 error code, a clear display photo, Daikin model stickers, affected rooms, reset result, and cooling-loss timeline and any recent gas top-up
🌐
JustAnswer
justanswer.co.uk › hvac › lcjs3-daikin-heat-pump-f3-malfunction.html
I have a Daikin heat pump and there is an f3 malfunction of discharge pipe temperature error on indoor unit. Can I power
February 25, 2023 - First, power off the system using the main switch or circuit breaker, then power it back on to attempt a reset. If the error persists, inspect the temperature sensor wiring and connections for damage or disconnection.
🌐
Silverback Air-con
silverbackaircon.sg › home › aircon error code › daikin error code › daikin f3 error code (an ultimate guide)
Daikin F3 Error Code (An Ultimate Guide) - Silverback Air-con
November 17, 2025 - But the chances of Daikin f3 error code attributing to PCB is extremely rare. Most of the time it is the thermistors that are malfunctioning. If it is normal. You will have to check if the refrigerant pressure is normal or not. If the refrigerant pressure is normal. It certainly has to be the PCB instead. But the chances of Daikin f3 error code attributing to PCB is extremely rare.
Find elsewhere
🌐
Star-supply
star-supply.com › content › Daikin-Troubleshooting Codes.pdf pdf
Trouble Shooting www.climatecenter.co.uk Daikin Trouble Shooting Guide
Daikin Trouble Shooting Guide · Past & Current Models · No. Code · No. Code · No. Code · 1 · 00 · 11 · E7 · 21 · UA · 2 · U4 · 12 · C7 · 22 · A5 · 3 · F3 · 13 · H8 · 23 · J9 · 4 · E6 · 14 · J8 · 24 · E8 · 5 · L5 · 15 · A3 · 25 ·
🌐
Daikin
daikin.com › - › media › Project › Daikin › daikin_com › products › ac › services › error_codes › pdf › sm-ts3_p7-8_howtocheck-pdf.pdf pdf
UNIT NO. 1 CODE UNIT NO. 1 3. Press MODE selector button. 4. Change the
8. Press the MODE button to exit from the · diagnosis mode. The display “ ” means the trial operation · mode. 9. Press the ON/OFF button twice to return · to the normal mode. Note: When the remote controller is left untouched · for 60 seconds, it returns to the normal mode. No.
🌐
Daikin
my.daikin.eu › content › dam › DASW › supportavdelningen › Felkoder_SM-TS3errorcode_chart.pdf pdf
Simple Self-Diagnosis by Malfunction Code After Sales Service Division (SM-TS3)
8. Press the MODE button to exit from the · diagnosis mode. The display “ ” means the trial operation · mode. 9. Press the ON/OFF button twice to return · to the normal mode. Note: When the remote controller is left untouched · for 60 seconds, it returns to the normal mode. No.
🌐
Airway Group
airway-group.co.uk › home › help & advice › daikin air conditioning fault codes explained [infographic]
Daikin Air Conditioning Fault Codes Explained [Infographic] | Airway
April 2, 2026 - Confused by the fault code showing on your Daikin air conditioner? This graphic explains the Daikin air conditioning fault codes simpy and clearly.
🌐
JustAnswer
justanswer.com › hvac › o1jbz-want-know-error-code-f3-means-soleus-air.html
Understanding Error Code F3 in Soleus Air and Daikin AC Units
The F3 error on Soleus Air and Heat split window units typically indicates a temperature sensor malfunction or a communication error between the indoor and outdoor units. First, reset the system by powering off for several minutes. Inspect the ...
🌐
JustAnswer
justanswer.com › hvac › 330vu-daikin-heat-pump-going-off-f3-error-code-high-discharge.html
Daikin F3 Error Code: Expert Solutions and Fixes
January 31, 2010 - The F3 error on a Daikin heat pump indicates high discharge temperature, often caused by restricted airflow or refrigerant issues. Check and clean air filters and outdoor coils to improve airflow. Inspect the compressor for unusual noise, which ...
🌐
Machine Answered
machineanswered.com › home › 20 daikin mini split error codes (quick troubleshooting)
20 Daikin Mini Split Error Codes (Quick Troubleshooting) - Machine Answered
March 26, 2026 - Remember you can clear the error code from your Mini Split by holding Set + Mode on the remote. Pressing Set and Mode on the remote control or the unit after viewing an error code can help clear it from the display, but that doesn’t reset the unit.
🌐
Penair
penair.com.au › home › how to reset a daikin air conditioner
Daikin Troubleshooting: Error Codes & Resetting A Daikin
November 10, 2025 - Note this code and reset your system by switching off the mains power and leaving it for 20 – 30 minutes. This reset may be all you need to fix the issue; however, if the system malfunctions again or doesn’t work after the reset, contact ...
🌐
RemoveandReplace.com
removeandreplace.com › home › home air conditioning › daikin air conditioner ac error codes
DAIKIN Air Conditioner AC Error Codes
December 22, 2022 - Daikin AC Error Code = M8 Error Code Definition = Malfunction of transmission between optional controllers for centralized control – Centralized control power disconnection What To Fix/Check/Replace = Centralized control reset switch ON – Defective transmission wiring – Central remote controller change
🌐
JustAnswer
justanswer.com › hvac › sdt3x-ceiling-model-brc1e63-unit-installed.html
Daikin BRC1E63 Error F3-23? Troubleshooting Help Guide
July 5, 2025 - Since you're unsure about resetting, have you noticed any unusual noises from the unit or any other signs of malfunction aside from the error code and blinking light? ... Hi there! I'm your HVAC expert. I understand your Daikin ceiling model is showing error code F3-23, and the on/off light ...
🌐
Skycon Air Pty Ltd
skyconair.com.au › home › error codes › daikin error codes › f3
Daikin F3 Error Code
May 9, 2025 - The F3 error code indicates a malfunction of the discharge pipe temperature sensor.