They have their own specific setup that I can’t remember (too many schematics in my brain). If it runs for a little bit and then shuts off for a while, kicks on for a bit and yada yada, check your condensate line, might be tripping a “safety switch.” Thats a quick fix, vacuum out the line. Check around the condenser and see if there’s a bunch of droppings. Rodents like to keep warm and chew on wires, those little bastards. Could be a number of things. But I’d start with the condy line. Answer from Deleted User on reddit.com
🌐
JustAnswer
justanswer.com › hvac › bvmqb-u4-error-daikin-indoor-unit-keeps.html
Daikin U4 Error Code: Expert Solutions and Fixes
December 27, 2018 - The long beep signals a fault detected by the control board. If cleaning doesn’t help, inspect the flap motor connector and wiring for damage. Reset the unit by turning off power for 5 minutes.
🌐
Penair
penair.com.au › home › how to reset a daikin air conditioner
Daikin Troubleshooting: Error Codes & Resetting A Daikin
November 10, 2025 - Dealing with a malfunctioning air conditioning system can be frustrating, but resetting your Daikin air conditioner can often resolve many common issues. This updated guide for 2024 provides step-by-step instructions on resetting Daikin ducted, split-system, and multi-split system units, decode error codes, and troubleshoot common problems.
Discussions

[Daikin VRV] [220 VAC] U4-01 Error Code Help
They have their own specific setup that I can’t remember (too many schematics in my brain). If it runs for a little bit and then shuts off for a while, kicks on for a bit and yada yada, check your condensate line, might be tripping a “safety switch.” Thats a quick fix, vacuum out the line. Check around the condenser and see if there’s a bunch of droppings. Rodents like to keep warm and chew on wires, those little bastards. Could be a number of things. But I’d start with the condy line. More on reddit.com
🌐 r/hvacadvice
6
4
September 6, 2024
Daikin support. my air/con heater got the error code U4-01
The U4-01 error on Daikin units typically indicates a temperature sensor or communication fault. First, power off the unit and check sensor wiring connections for looseness or damage. Clean the air filters and ensure no obstructions block airflow. Reset the system by holding the ON button for ... More on justanswer.com
🌐 justanswer.com
1
December 22, 2022
Daikin Mini split- error code U4
There’s a specific process to it. Need a Daikin d checker tool to really further diagnose More on reddit.com
🌐 r/hvacadvice
7
2
November 25, 2023
daikin u4 fault code the wiring is ok on the control think it maybe pcb when looked in outdoor unit the fan fuse blown i have replaced but nothing is there a reset
Re: Daikin u4 fault code the wiring is ok on the control... Hi hoping you can help, I’ve recently had an error code U4. The unit works and after 45min cuts out, this is then code U4 appears. If I reset the power from the main RCD fuse box from my house it starts working again. More on fixya.com
🌐 fixya.com
3
November 29, 2012
People also ask

How do you reset a Daikin fault?
To reset a Daikin fault, you must enter the diagnostic mode using the remote control to retrieve the fault code.  Then, use the On/Off button to reset the unit.  If the fault persists, professional assistance may be required.
🌐
penair.com.au
penair.com.au › home › how to reset a daikin air conditioner
Daikin Troubleshooting: Error Codes & Resetting A Daikin
Where is the reset button on a Daikin?
The reset function for a Daikin air conditioner is typically activated through the remote control.  Instead of a separate reset button, the On/Off button acts as the Daikin Air Conditioner reset button.
🌐
penair.com.au
penair.com.au › home › how to reset a daikin air conditioner
Daikin Troubleshooting: Error Codes & Resetting A Daikin
Why is my Daikin air conditioner not starting?
If you experience issues like your Daikin AC not turning on, check for any power supply issues first.  If the power supply is fine, try resetting the unit using the remote control.  Persistent starting issues might indicate a more serious problem needing professional attention.
🌐
penair.com.au
penair.com.au › home › how to reset a daikin air conditioner
Daikin Troubleshooting: Error Codes & Resetting A Daikin
🌐
JustAnswer
justanswer.com › hvac › pphzc-daikins-inverter-giving-u4-error-code.html
Daikin Inverter U4 Error Code? Expert Troubleshooting Guide
August 3, 2024 - The U4 error on a Daikin inverter typically indicates a communication or sensor fault. First, power off the unit for 5 minutes to reset. If persistent, check the indoor unit’s PCB connections and wiring harness for loose or damaged cables.
🌐
Star-supply
star-supply.com › content › Daikin Single- Multi -U4 Error Code.pdf pdf
Daikin Single-Multi U4 Error Codes
If correct voltage is present on the outside wire, reconnect the wire and turn on the unit. If the U4 error still
🌐
Reddit
reddit.com › r/hvacadvice › [daikin vrv] [220 vac] u4-01 error code help
r/hvacadvice on Reddit: [Daikin VRV] [220 VAC] U4-01 Error Code Help
September 6, 2024 -

My air conditioning failed on me some time today when I was at work, and when I returned home it was 92° inside my home. Figures this would happen during the (hopefully) hottest week of the year in Los Angeles. This system was professionally installed in June of 2020, and has worked without issue until now. The company that did it was bought out by another larger firm, and they are unable to send a tech out for another 17 days. I’m kind of SOL there. I change the filters every six months in the air handlers, and regularly hose down/clean the exterior unit. With a basic visual inspection, it does not appear that there are any blockages/impediments to air flow. I have tried powering off both the exterior unit and both interior air handlers by switching off the breakers on two separate occasions. The cooling works for about 10 minutes and then the error message is displayed again on the interior control panel. Any ideas?

🌐
Daikin
daikin.com › products › ac › services › error_codes
Error Codes | After Sales Service | Air Conditioning and Refrigeration | Daikin Global
Error Code Search offers information on the cause of the malfunction and the status of your air conditioner by entering the error code.
Find elsewhere
🌐
Daikin India
daikinindia.com › product-services › product-services › error-codes
Error Codes | Daikin
Customer Support Information: WhatsApp us your query @ 9871409300. Call Our Customer Contact Centre: 011-40319300 / 1860 180 3900 or Write To Us at customerservice@daikinindia.com X
🌐
JustAnswer
justanswer.com › hvac › kv8uf-daikin-support-air-con-heater-error-code-u4-01.html
Daikin U4-01 Error Code? Troubleshooting Help & Fix Guide
December 22, 2022 - First, power off the unit and check sensor wiring connections for looseness or damage. Clean the air filters and ensure no obstructions block airflow. Reset the system by holding the ON button for 10 seconds.
🌐
Daikin
my.daikin.eu › content › dam › DASW › supportavdelningen › Felkoder_SM-TS3errorcode_chart.pdf pdf
Simple Self-Diagnosis by Malfunction Code After Sales Service Division (SM-TS3)
8. Press the MODE button to exit from the · diagnosis mode. The display “ ” means the trial operation · mode. 9. Press the ON/OFF button twice to return · to the normal mode. Note: When the remote controller is left untouched · for 60 seconds, it returns to the normal mode. No.
🌐
Beaconsaves
beaconsaves.com › blog › daikin-mini-split-u4-error-code
Daikin Mini Split U4 Error Code: What It Means & What to Check | Beacon Services & Appliances
No. U4 is typically a control or communication problem, not a refrigerant shortage code. ... A reset may clear the display briefly, but if the communication problem remains, the code will usually return.
🌐
Silverback Air-con
silverbackaircon.sg › home › aircon error code › daikin error code › ultimate guide to daikin u4 error code
Ultimate Guide to Daikin U4 Error Code - Silverback Air-con
October 28, 2025 - Is your Daikin system displaying the dreaded U4 error code? Learn how to resolve this issue with our ultimate guide to Daikin U4 error code.
🌐
Reddit
reddit.com › r/hvacadvice › daikin mini split- error code u4
r/hvacadvice on Reddit: Daikin Mini split- error code U4
November 25, 2023 -

I’m a little lost on trying to trouble shoot this one, any advice is appreciated. I purchased a 2 ton single head Daikin minisplit system online a few months ago to install in a workshop in my backyard, that I’m in the process of renovating. Everything was going smoothly with the install, doing the majority of the work myself. I am a builder by trade and have done several minisplit installs over the years. I hired an HVAC tech to connect the refrigerant linesets, and evacuate/ pressure test the lines. As far as I can tell the problem came about when I connected the wiring. Unfortunately I crossed the signal line and one of the power lines at the outdoor unit control wiring. When I went to fire up the system, the indoor unit status light started flashing blue, indicating a system error. I realized what had happened then and corrected the wiring. No luck, still flashing blue. Error code retrieval at this point, at the remote control reads U4: communication error. Next I tried pulling the outdoor unit control panel to see if there is a blown fuse. I was able to locate 3 separate fuses but none of them tested bad. Pulled the indoor unit control board and there is one fuse which also checked out ok. Last I try running a separate jumper wire externally to eliminate the possibility that there is an unseen break in the original signal wire. I then try turning the system on again, same thing: indoor unit status light flashing blue and error code U4. Any ideas?

🌐
Quality Home Air Care
qualityhomeaircare.com › daikin-thermostat-error-code-u4-01-troubleshooting
Daikin Thermostat Error Code U4-01 Troubleshooting Guide – Quality Home Air Care
Reset To Factory Settings (If Advised): Some Daikin models support a factory reset. Document current settings before resetting, then reconfigure the unit from scratch to see if U4-01 is cleared. Note: If the problem persists after these steps, it is likely tied to a hardware fault or a more ...
🌐
ADK Kooling
adk.co.uk › home › air conditioning › daikin error code u4 — vrv communication fault explained
Daikin Error Code U4 | Communication Fault Fix | ADK London
March 23, 2026 - U4 is the Daikin VRV error code we see most often, and it’s typically resolved on the first visit.
Price   $$
Address   Daneshill House, 3 Waterloo Road, UB8 2QX, Uxbridge
🌐
Silverback Air-con
silverbackaircon.sg › home › articles › daikin error codes and how much it costs to fix
Daikin Error Codes and How Much It Costs to Fix - Silverback Air-con
April 20, 2026 - In separate entries, we have exhaustively covered several Daikin error codes and their corresponding fixes, all of which are linked below. A hard reset of your Daikin aircon tends to clear most issues and glitches caused by residual charges in the air conditioning system.
🌐
Daikin
daikin.com › - › media › Project › Daikin › daikin_com › products › ac › services › error_codes › pdf › sm-ts3_p7-8_howtocheck-pdf.pdf pdf
UNIT NO. 1 CODE UNIT NO. 1 3. Press MODE selector button. 4. Change the
8. Press the MODE button to exit from the · diagnosis mode. The display “ ” means the trial operation · mode. 9. Press the ON/OFF button twice to return · to the normal mode. Note: When the remote controller is left untouched · for 60 seconds, it returns to the normal mode. No.
🌐
Airway Group
airway-group.co.uk › home › help & advice › daikin air conditioning fault codes explained [infographic]
Daikin Air Conditioning Fault Codes Explained [Infographic] | Airway
April 2, 2026 - UA – Combination error of indoor/BS/outdoor unit, setting error of PCB at site – There is an incorrect combination of indoor, BS or outdoor units (the wrong quantity or models, for example). If you’re in the Cambridge area, our locally based air-conditioning engineers can fix the issue the same day. Further afield? Book a Daikin repair service or just contact us.
🌐
Fixya
fixya.com › home › forum › heating & cooling › cfm › daikin r410a split system air conditioner
SOLVED: Daikin u4 fault code the wiring is ok on the - Cfm Daikin R410a Split System... | Fixya
November 29, 2012 - If the fuse has blow there is a fault, check all components in outdoor units, Fans compressors ect a power outage will cause this fault and just replacing the fuse will more than likely cause more damage to the system without checking components first, To reset power off outdoor then back on this should clear it, ... You can't post conmments that contain an email address. ... An expert who has achieved level 1. ... An expert that has 1 follower. ... An expert who has achieved level 1. ... An expert that has 1 follower. ... Re: Daikin u4 fault code the wiring is ok on the control... ... You can't post conmments that contain an email address. ... Sounds like an interconnecting wiring error.
🌐
AirReps
airreps.com › 2025 › 11 › understanding-the-u4-error-code-in-daikin-vrv-systems
Understanding the U4 Error Code in Daikin VRV Systems - AirReps
November 19, 2025 - A U4 error code almost always requires professional service. A qualified VRV technician will have the proper tools to test communication signals, measure voltages, and diagnose which component is causing the failure. They can also safely work with the electrical systems involved. To minimize the risk of communication errors in the future, consider these preventive measures: Schedule regular maintenance with a qualified Daikin technician who can inspect connections and identify potential issues before they cause failures