Pinout depends on the hardware, but maybe this is correct: https://powerforum.co.za/topic/11977-sunsynk-88-with-pylontech-us3000c-bms-cable/ CAT5/CAT6 cable should be sufficient for the job, keep in mind, that RS485 is a bus (RS232 is point to point), so maybe you’ll have to terminate the ends (bu… Answer from Udo_Hartmann on community.openhab.org
🌐
openHAB Community
community.openhab.org › setup, configuration and use › beginners
Modbus over RS485 (RJ45 to DB9) cable lenghth and pinout - Beginners - openHAB Community
June 6, 2023 - Hi All I am about to take delivery of my SunSynk inverter which does not seem to have any binding support (using the new SunSynk logger). So it appears that I will have to revert to MODBUS over RS485, so I have a few q…
Discussions

rs485 - What's the correct pinout for Half Duplex RS-485 in an RJ-45 connector? - Electrical Engineering Stack Exchange
I'm working on a project that involves some long-distance communication using RS-485 and MAX485 and MAX3485 ICs. My project features custom PCBs (essentially Arduino/Teensy Shields) which react and More on electronics.stackexchange.com
🌐 electronics.stackexchange.com
RJ45 to RS485 pinout
Looking over your Twido program I have noticed that both RS485 ports (mini-din) and the terminal block option block share the same Modbus address of 1. ... Thanks, i'll try to change it and see if it works . You must log in or register to reply here. ... Hello guys, I am trying to control a ATV12 via Modbus Poll software. I need the connection diagram for Altivar Modbus RJ45 ... More on plctalk.net
🌐 plctalk.net
6
April 27, 2011
Pinout RTU/Modbus RS485 - SiePortal - Siemens
Loading · Please enable JavaScript to continue using this application More on sieportal.siemens.com
🌐 sieportal.siemens.com
Modbus Cable: RJ45 - RJ11 Cable Pin-Out? - Vision & Samba PLC + HMI Controllers & VisiLogic Software - Unitronics Support Forum: Programmable Controllers (PLC + HMI All-in-One)
Hi All, I want to control an Invertek VSD using Modbus communication similar to link below. I need a cable connect the drive to the V570 which needs a RJ45 on drive end and RJ11 on V570 end. Does anybody know the pinout of the RJ45 - RJ11 cable please? Thanks in advance... Gerard More on forum.unitronics.com
🌐 forum.unitronics.com
August 11, 2019
🌐
PLCS.net
plctalk.net › home › forums › q & a › plc questions and answers
RJ45 to RS485 pinout | PLCtalk - Interactive Q & A
April 27, 2011 - I use following devices: HMI XBTGT 4330 7" Programming software: VijeoDesigner 4.6.0.7613 Twido PLC TWDLCAE40DRF Programming software: TwidoSuite 2.0 Altivar 71 Ethernet communication between HMI and PLC works fine, i can set the speed on HMI and correct value is displayed in animation table on PLC. I used following settings on Altivar: Communication - Modbus Network: Address: 2 Baudrate: 19200 Data bits: 8 Time between frames: 10 Command: Ref.channel 1: Modbus Ch1 active Profile Not separ.
🌐
Improwis
improwis.com › tables › rj45.webt
RJ45 and RJ11 pinouts for data buses and connections
! CAN2.0 CAN_H CAN_L CANGND (power) CAN2.0 CAN_H CAN_L CANGND (shield) (GND) (power) [ref] CAN2.0,ATV31 CAN_H CAN_L CANGND ModbD1 ModbD0 VP GND [ref] D1,D0=RS485 MODBUS signals; also CANopen VW3CANTAP2[ref] Optidrive CAN_L CAN_H GND Optibus- Optibus+ +24V 485Rx- 485Rx+ [ref] SolisInverters GND CANH CANL [ref] BYD batteries RS485A RS485B CANH CANL [ref] PylonTech n.c.
Find elsewhere
🌐
Schneider Electric
productinfo.schneider-electric.com › tesys_t_user_guides › doca0130-tesys-t-ltmr-mmc-modbus-comm-guide › English › BM_TeSys_T LTMR Modbus Guide_53457272_T001006402.xml › $ › CHP_WiringoftheModbusNetwork_53457272_T001006408
Wiring of the Modbus Network - TeSys T User Guides
The wiring diagram for connection of LTMR controllers installed in an enclosure to the RS 485 bus via the RJ45 connector is as follows: 1 Primary (PLC, PC, or communication module) with line terminator · 2 Modbus shielded cable with two RJ45 connectors VW3 A8 306 R••
🌐
Unitronics
forum.unitronics.com › vision, samba, jazz and m90 plc + hmis & software › vision & samba plc + hmi controllers & visilogic software
Modbus Cable: RJ45 - RJ11 Cable Pin-Out? - Vision & Samba PLC + HMI Controllers & VisiLogic Software - Unitronics Support Forum: Programmable Controllers (PLC + HMI All-in-One)
August 11, 2019 - Hi All, I want to control an Invertek VSD using Modbus communication similar to link below. I need a cable connect the drive to the V570 which needs a RJ45 on drive end and RJ11 on V570 end. Does anybody know the pinout of the RJ45 - RJ11 cable please? Thanks in advance... Gerard
🌐
OutBack Power Technologies
forum.outbackpower.com › viewtopic.php
Modbus RJ45 pinout - OutBack Power Technologies User Forum
May 24, 2024 - I take all the green outback cables, whose conductors are aluminum foil, and replace them with standard CAT5/6 Ethernet RJ45 cables. I'd do that same thing here. The two protocols: ethernet and modbus use different electrical connections and signals. They use the same RJ45 cable configuration.
🌐
Beckhoff
infosys.beckhoff.com › content › 1033 › fbb-x730 › 9172104075.html
Modbus RS485 connection
Pin 1 is 5 VDC and 3 is GND for the active termination resistor. These must never be misused for other functions, as this can lead to destruction of the device. Pin 2 and pin 4 are the Modbus signals. These must never be swapped over, as this will prevent communication.
🌐
Chipkin
docs.chipkin.com › articles › modbus-rs485-physical-layer-wiring-and-termination-reference
RS-485 Physical Layer Wiring & Termination Reference for Modbus RTU
March 12, 2026 - Complete RS-485 physical layer specification for Modbus RTU networks — wiring diagrams, termination resistor placement, polarization, cable selection, maximum distances, connector pinouts, and grounding best practices.
🌐
Ersa Electronics
ersaelectronics.com › home › blog › interface ic chips
RS485 Standard: Wiring, Modbus, Ethernet, IC Guide
August 29, 2025 - The answer is yes—RJ45 is only a connector type. Many industrial devices map RS485 differential lines onto RJ45 pins. For example, A/B signals are often placed on pins 1 and 2, while pin 7/8 may be used for ground.
🌐
Reddit
reddit.com › r/plc › standard connector/pinout for rs-485?
r/PLC on Reddit: Standard connector/pinout for RS-485?
July 26, 2022 -

I'm developing some automation equipment that will go into an overseas factory. The factory would like to communicate with the equipment and I'm recommending to do so via RS485; however, I can't seem to find any standard or best-practice connectors and/or pinouts. Seems like DB9 or RJ45 would be good options, but searching online shows a variety of pinouts. I'd imagine that you'd need adapters for different pieces of equipment from different manufacturers to talk to each other. Is that they way it is, or am I overlooking a standard? Thanks!

Top answer
1 of 6
4
Standard: two screw terminals labeled + and -. See www.Modbus.org The problem with your idea is that often RS-485 requires termination resistors to prevent communication problems from reflections. So with screw terminals we can just insert the resistor. If anything make it plug-in. That way it is a “plug” but one I can easily wire up. With DB-9, RS-485, etc., we can’t do any of that. We are back to making goofy connectors by hand. The pins require special tools and often fall out. DB9 was used because DB25 was huge. DB25 existed for mouse immunity with every other pin grounded back in the teletype days with massive noise problems if the day. Connections were still soldered so a hollow pin made lots of sense at that time. Plus DB9 is already associated with RS-232. RJ-45 is Ethernet. Reusing these (which some vendors do) just creates confusion. If I see DB9, there’s a 95% chance it’s RS-232. There are vendors who do this (Allen Bradley) and it causes nothing but problems. People are constantly trying to plug an Ethernet device into the RS-485 “DPI” ports. Now there are exceptions and this is also why AB and others do it. A common configuration is where you have say an RJ-45 or RJ-11 or RJ-12 6P6C connector bug two pins carry 24 V and ground abc 2 carry RS-485/Modbus. This is a “remote keypad” port used on a lot of VFDs on the market. It has the convenience that the port can double as a programming or networking port and that if the factory cable breaks you can get a new one anywhere.
2 of 6
3
There’s no standard, except for everyone’s standard.
🌐
VictronEnergy
communityarchive.victronenergy.com › questions › 247255 › modbus-pinout-cerbo-1.html
Modbus pinout cerbo - VictronEnergy
For the cable, as far as I know the Cerbo series only supports modbus RS485 using a USB to serial adaptor that uses the ftdi chip - the victron one referenced earlier is the one I use. The RJ45 sockets only officially support CanBus/NMEA2000 or Ethernet.
🌐
Schneider Electric
se.com › support · / › search faqs · / › fa198270
What is the pinout to the RS485 cable needed to connect an M340 to a Unity Quantum RJ45 modbus port? | Schneider Electric UK
Note: If the cable is 10 feet or longer a 120 ohm resistor will be needed across pins 1 and 2 on the Quantum side as well as pins 4 and 5 on the M340 side.…
🌐
Red Lion Support
support.redlion.net › hc › en-us › articles › 6765664174605-RS-485-Wiring
RS-485 Wiring – Red Lion Support
For 4 wire RS485 communication, you will use Pins 1, 2, 3 and 4 with Pin 6 being used for Common. Redlion sells a cable that goes from RJ45 connector on one end to bare wires on the other end.
🌐
DIY Solar Forum
diysolarforum.com › general discussion › diy solar general discussion
Growatt 6000T - RJ45 to RS485 pinout - Help | DIY Solar Power Forum
June 17, 2021 - Have never tied anything to Growatt rs485 port, but as DThames stated above the spf-6000t-dvm-mvp manual indicates using BMS port - Click to expand... I found that pin out diagram for the BMS port in my manual as well. I wasn't completely sure if it is safe to assume the second rj45 port labeled rs485 on my growatt would have the same pin out.